AutoSense, Configuration Label and Dump Mode
AutoSense sets the sensitivity of the transmissive (gap) sensor, measures and
stores the form (label) and gap lengths. For more details on media sensing
and sensors see Top of Form Sensing. To activate the AutoSense feature:
- Load labels into the printer. Verify that the reflective sensor's
location (red light) is under the transmissive sensor for label mode operations.
(Click
here for diagram)
- Turn OFF printer power. Set Batch mode. Do not use the peel mode.
- Press and hold the FEED button while turning ON printer power.
- Release the FEED button when the status indicator begins to flash and the
label will begin to advance.
- The printer will advance 3-4 labels while performing the sensor
adjustment. When the adjustment is complete, a status summary label
will
be printed and the printer will be placed in Diagnostic Dump mode.
- Press the FEED button to exit the Dump mode. Remove excess labels.