Discussion:.

Pax4 Ribbon Low Early Warning


Zebra Print Engines are capable of early warnings notifications when the printer is low on ribbon in two different ways, through the Early Warning function or the Ribbon Low mode. (Pax 4 firmware V60.15.2Z or higher is required).  To activate the early warning for ribbon and media, the EARLY WARNING MEDIA must first be enabled. Enabling the "EARLY WARNING MEDIA" when the printer is set to thermal transfer mode, then enables early warnings for ribbon. The Zebra Print Engines are also capable of warning for ribbon low, without tracking media. This is referred to as RIBBON LOW MODE. Enabling EARLY WARNING MEDIA overrides the RIBBON LOW MODE. The  "RIBBON LENGTH" and "RIBBON REPLACED?" menus should be displayed whenever the EARLY WARNING is activated. The other ribbon low menus "RIBBON LOW MODE" and "RIBBON LOW OUTPUT" are always shown.

If EARLY WARNING MEDIA is enabled, the RIBBON LOW MODE is not functional. However, EARLY WARNING MEDIA monitors both media and ribbon based on EARLY WARNING MEDIA settings. The settings for ribbon low mode are still available and saved, so that if EARLY WARNING MEDIA is disabled in the future, the RIBBON LOW MODE settings will take effect.

Table 1: LCD Display Functions

LCD Display

Function

RIBBON LENGTH

- 450M 1476 FT +

Set Ribbon length for Early Warning

This parameter appears only when the printer is set for Thermal transfer operation and EARLY WARNING MEDIA is enabled.

Default: 450M/1476 FT

Range: 100M/328 FT to 900M/ 2953FT in 50M increments

To change the value shown:

  1. Press the left or right oval to set the value to match the length of the ribbon that you are using. As the print engine is printing, it uses this number to determine the amount of remaining ribbon. When the printhead is opened and then closed after a ribbon warning is received, the LCD prompts with RIBBON REPLACED?.
  2. If you replaced the ribbon, press the right oval to select YES to clear the warning and reset the ribbon counter. If you did not replace the ribbon, press the left oval to select NO.

 

RIBBON REPLACED?

NO                       YES

Reset Ribbon Counter for Early Warning or Ribbon Low Mode

This parameter appears only when the printer is set for Thermal Transfer operation and EARLY WARNING MEDIA is enabled.

To reset the ribbon counter:

  1. If you replaced the ribbon, press the right oval to select YES. If you did not replace the ribbon, press the left oval to select NO.

 

RIBBON LOW MODE

-              25M           +

Set Ribbon Low Mode

When the Ribbon Low feature is off, the output signal (Pin 9) does not function, the LOW RIBBON warning is not displayed, and the print engine continues to print until it runs out of ribbon.

When the Ribbon Low feature is set to any of the lengths, output signal (Pin 9) on the applicator port is functional. When the amount of ribbon on the supply spindle reaches the specific length, the ribbon warning is displayed on the LCD display, a signal is asserted to the applicator based on the ribbon low output and if the alert function is enabled, an alert is also sent.

Defaults: 25M (110 only- ENABLED for 170)

Selection: OFF, 25M, 50M, 75M, 100M (110 only-DISABLED for 170)

To change the value shown

  1. Press the left or right oval to scroll through the options.

 

RIB LOW OUTPUT

ACTIVE HIGH

Set Ribbon Low Output

When the Ribbon Low feature is set to any of the lengths, output signal (Pin 9) on the applicator port is functional. When the amount of ribbon on the supply spindle reaches the specific length, a signal is asserted as either HIGH or LOW to the applicator based on this selection.

Default: ACTIVE HIGH

Selection: ACTIVE HIGH, ACTIVE LOW

To change the value shown

  1. Press the left or right oval to scroll through the options.

 

Types of warnings:

LCD Display

WARNING RIBBON LOW is displayed when the amount of ribbon remaining on the supply spool is below a specific threshold level

Applicator Port-

Pin 9 Signal asserted when the amount of ribbon remaining on the supply spool is below a specific threshold level. It is asserted HIGH if the Ribbon Low Output is set to active high or asserted LOW if the Ribbon Low Output is set to active low. If the Ribbon Low Mode is set to off and Early warning media is disabled, this output lead is disabled.

Summary of WARNING RIBBON LOW activation:

RIBBON LOW MODE

The ribbon low early warning message and signal will be activated in the following conditions:  

For example, if the ribbon low mode is set any 25M and the ribbon drops below 25M of ribbon remaining, the message will be displayed on the LCD Display and the signal asserted on pin 9 of the applicator. If the alert function is enabled, an alert is also sent.

EARLY WARNING MEDIA

The ribbon low early warning message and signal will be activated in the following conditions:

EARLY WARNING MEDIA

 

Not Activated

Activated

110PAX4

DISABLED

ENABLED

(85% used up)

170PAX4

DISABLED

ENABLED

(85% used up)

For example, if the early warning media is enabled and the ribbon drops below 15% of ribbon remaining, the message will be displayed on the LCD Display and the signal asserted on pin 9 of the applicator. If the alert function is enabled, an alert is also sent.

Thus, when the early warning media is disabled and ribbon low mode is set to OFF, there is no ribbon low warning will be displayed and pin 9 is disabled.


Notice: Zebra Technologies Corporation makes no representations about the suitability of this documentation for any purpose. It is provided "as is", for your information only, without warranty of any kind, either expressed or implied, including, but not limited to, implied warranties of merchantability, fitness for a particular purpose and non-infringement.