Title: Using Real Time Clock Option within a Stored Label Format 

Symptoms: Real time values do not print if used within a stored label format 

Facts or Affected Items: 

EPL, RTC ,  Real Time option,   Clock,   Date,    Time


Details

Time/date is considered to be a variable within EPL.   For the data/time to print one needs to specify the variable when recalling the label  format with a "?"

Example:

Stored Label format:

FK"1"

FK"1"

FS"1"

q600

A100,200,0,1,1,1,N,TD

FE

 

Recalling format example:

FR"1"

?

P1

Note the "?".  


Notice: Zebra Technologies Corporation makes no representations about the suitability of this documentation for any purpose. It is provided "as is", for your information only, without warranty of any kind, either expressed or implied, including, but not limited to, implied warranties of merchantability, fitness for a particular purpose and non-infringement.